Blood-repellent materials: A new approach to medical implants
Colorado State University News Jan 25, 2017
A specially grown, Âsuperhemophobic titanium surface thatÂs extremely repellent to blood. The material could form the basis for surgical implants with lower risk of rejection by the body.
ItÂs an outside–the–box innovation achieved at the intersection of two disciplines: biomedical engineering and materials science. The work, recently published in Advanced Healthcare Materials, is a collaboration between the labs of Arun Kota, assistant professor of mechanical engineering and biomedical engineering; and Ketul Popat, associate professor in the same departments.
Kota, an expert in novel, Âsuperomniphobic materials that repel virtually any liquid, joined forces with Popat, an innovator in tissue engineering and bio–compatible materials. Starting with sheets of titanium, commonly used for medical devices, their labs grew chemically altered surfaces that act as perfect barriers between the titanium and blood. Their teams conducted experiments showing very low levels of platelet adhesion, a biological process that leads to blood clotting and eventual rejection of a foreign material.
A material Âphobic to blood might seem counterintuitive, the researchers say, as often biomedical scientists use materials Âphilic to blood to make them biologically compatible. ÂWhat we are doing is the exact opposite, Kota said. ÂWe are taking a material that blood hates to come in contact with, in order to make it compatible with blood. The key innovation is that the surface is so repellent, that blood is tricked into believing thereÂs virtually no foreign material there at all.
The undesirable interaction of blood with foreign materials is an ongoing problem in medical research, Popat said. Over time, stents can form clots, obstructions, and lead to heart attacks or embolisms. Often patients need blood–thinning medications for the rest of their lives  and the drugs arenÂt foolproof.
ÂThe reason blood clots is because it finds cells in the blood to go to and attach, Popat said. ÂNormally, blood flows in vessels. If we can design materials where blood barely contacts the surface, there is virtually no chance of clotting, which is a coordinated set of events. Here, weÂre targeting the prevention of the first set of events.Â
The researchers analyzed variations of titanium surfaces, including different textures and chemistries, and they compared the extent of platelet adhesion and activation. Fluorinated nanotubes offered the best protection against clotting, and they plan to conduct follow–up experiments.
Growing a surface and testing it in the lab is only the beginning, the researchers say. They want to continue examining other clotting factors, and eventually, to test real medical devices.
Go to Original
ItÂs an outside–the–box innovation achieved at the intersection of two disciplines: biomedical engineering and materials science. The work, recently published in Advanced Healthcare Materials, is a collaboration between the labs of Arun Kota, assistant professor of mechanical engineering and biomedical engineering; and Ketul Popat, associate professor in the same departments.
Kota, an expert in novel, Âsuperomniphobic materials that repel virtually any liquid, joined forces with Popat, an innovator in tissue engineering and bio–compatible materials. Starting with sheets of titanium, commonly used for medical devices, their labs grew chemically altered surfaces that act as perfect barriers between the titanium and blood. Their teams conducted experiments showing very low levels of platelet adhesion, a biological process that leads to blood clotting and eventual rejection of a foreign material.
A material Âphobic to blood might seem counterintuitive, the researchers say, as often biomedical scientists use materials Âphilic to blood to make them biologically compatible. ÂWhat we are doing is the exact opposite, Kota said. ÂWe are taking a material that blood hates to come in contact with, in order to make it compatible with blood. The key innovation is that the surface is so repellent, that blood is tricked into believing thereÂs virtually no foreign material there at all.
The undesirable interaction of blood with foreign materials is an ongoing problem in medical research, Popat said. Over time, stents can form clots, obstructions, and lead to heart attacks or embolisms. Often patients need blood–thinning medications for the rest of their lives  and the drugs arenÂt foolproof.
ÂThe reason blood clots is because it finds cells in the blood to go to and attach, Popat said. ÂNormally, blood flows in vessels. If we can design materials where blood barely contacts the surface, there is virtually no chance of clotting, which is a coordinated set of events. Here, weÂre targeting the prevention of the first set of events.Â
The researchers analyzed variations of titanium surfaces, including different textures and chemistries, and they compared the extent of platelet adhesion and activation. Fluorinated nanotubes offered the best protection against clotting, and they plan to conduct follow–up experiments.
Growing a surface and testing it in the lab is only the beginning, the researchers say. They want to continue examining other clotting factors, and eventually, to test real medical devices.
Only Doctors with an M3 India account can read this article. Sign up for free or login with your existing account.
4 reasons why Doctors love M3 India
-
Exclusive Write-ups & Webinars by KOLs
-
Daily Quiz by specialty
-
Paid Market Research Surveys
-
Case discussions, News & Journals' summaries