Study illustrates precise, minimally invasive way to measure heart function in children

ANI Mar 21, 2019

A new study has illustrated how a novel minimally invasive method using catheter-based ultrasound to measure heart function performed with similar precision as compared to a traditional highly invasive device.


Currently, most devices used to monitor cardiac output are adapted from adult patients with limited use in children, due to differences in size, technical limitations, and risk of complications. The research was published in the Online First edition of Anesthesiology, the peer-reviewed medical journal of the American Society of Anesthesiologists (ASA).

Cardiac output, the volume of blood pumped by the heart per minute, is a crucial component of vital signs monitored in surgical patients. Evaluation by physical examination of critically ill children is often imprecise. Physicians have almost no available alternatives to manage and measure how a pediatric patient's heart is responding to different therapies, since there are no practical and precise minimally invasive ways to measure cardiac output in infants and young children.

"This new technology is less invasive than earlier technologies and can be used while patients are awake, which makes it more clinically practical for young children," said Theodor S Sigurdsson, MD, Paediatric Anesthesiologist, Children's Hospital, University Hospital of Lund in Sweden.

"Our results demonstrate that this technology was not only easily adaptable in young children but also very accurate and precise. It could aid further validation of the next generation of non-invasive hemodynamic monitors in the intensive care setting." In the study, researchers used ultrasound sensors to produce precise measurements that were comparable to those obtained using a more traditional method of placing a probe around the patient's aorta to measure heart function. 43 children between the ages of one and 44 months scheduled for corrective cardiac surgery were studied.

Researchers measured heart function using both the invasive perivascular flow probe and the new minimally invasive ultrasound technology. After administering a saline injection, researchers were able to detect blood dilution levels using ultrasound sensors attached to an arteriovenous loop connected to catheters in the patient's internal jugular vein and radial artery.

After surgery, five consecutive repeated cardiac measurements were performed using both methods simultaneously, for a total of 215 cardiac output measurements. The ultrasound sensors showed a statistically similar precision for measuring cardiac output when compared to the results obtained using the periaortic flow probe.

In an accompanying editorial, Christine T Trieu, MD, physician anesthesiologist, at the Ronald Reagan UCLA Medical Center, noted there are very few commercially available, precise cardiac output monitoring devices for infants and young children. "Despite the encouraging results from this study, there are still many challenges in developing the ideal cardiac output monitor for pediatric patients," said Dr Trieu. "This is the reason why we welcome and applaud the study by Dr Sigurdsson et al. It offers the possibility of a simple and reliable method that uses arterial line and central line to measure cardiac output in children of all sizes."

Only Doctors with an M3 India account can read this article. Sign up for free or login with your existing account.
4 reasons why Doctors love M3 India
  • Exclusive Write-ups & Webinars by KOLs

  • Nonloggedininfinity icon
    Daily Quiz by specialty
  • Nonloggedinlock icon
    Paid Market Research Surveys
  • Case discussions, News & Journals' summaries
Sign-up / Log In
x
M3 app logo
Choose easy access to M3 India from your mobile!


M3 instruc arrow
Add M3 India to your Home screen
Tap  Chrome menu  and select "Add to Home screen" to pin the M3 India App to your Home screen
Okay