FDA allows marketing of test to identify organisms that cause bloodstream infections and provide antibiotic sensitivity results
FDA Press Announcements Feb 26, 2017
The U.S. Food and Drug Administration allowed marketing of the PhenoTest BC Kit, performed on the Pheno System. This is the first test to identify organisms that cause bloodstream infections and provide information about which antibiotics the organism is likely to respond to antibiotic sensitivity. The test also reduces the amount of time it takes to provide this important information, which can guide antibiotic treatment recommendations more quickly.
"By identifying organisms and knowing earlier which antibiotics the organism is likely to respond to, health care professionals can treat patients with bloodstream infections more appropriately," said Alberto Gutierrez, PhD, director of the Office of In Vitro Diagnostics and Radiological Health at the FDAÂs Center for Devices and Radiological Health.
Unlike traditional identification and antibiotic susceptibility tests that may take 24 to 48 hours after detection in a positive blood culture to provide test results, the PhenoTest BC Kit can identify bacteria or yeast from a positive blood culture in approximately 1.5 hours. For certain organisms, the test also provides important information to guide treatment recommendations in approximately 6.5 hours after the organisms are detected from blood cultures.
The test can identify 14 different species of bacteria and two species of yeast that cause bloodstream infections, while also providing antibiotic sensitivity information on 18 selected antibiotics for a subset of the identified organisms as appropriate. The test will also identify the presence of two indicators of antibiotic resistance, which can occur when potentially harmful bacteria change in a way that reduces or eliminates the effectiveness of antibiotics.
The PhenoTest BC Kit works by measuring the similarity of the infection–causing organismÂs genetic material to DNA known to be unique to specific bacteria or yeast. Once the organism is identified, it is mixed with antibiotics and the growth of the bacteria is measured by time–lapse images. If the organism does not grow when the antibiotic is present, this means that an antibiotic can possibly be used for treatment.
The FDA reviewed the data for the PhenoTest BC Kit through the de novo premarket review pathway, a regulatory pathway for devices of a new type with low–to–moderate–risk that are not substantially equivalent to an already legally marketed device and for which special controls can be developed, in addition to general controls, to provide a reasonable assurance of safety and effectiveness of the devices. The FDAÂs decision to allow marketing was based largely on its review of the sponsorÂs primary clinical study of 1,850 positive blood cultures. In this study, the PhenoTest BC Kit provided correct identification of the bacteria or yeast in the positive blood culture more than 95 percent of the time. Results for testing whether the bacteria were sensitive to antibiotics were also accurate when compared to traditional tests.
Risks associated with use of the PhenoTest BC Kit include false positive findings, which can occur when an individual not infected with organisms that cause bloodstream infections receives a test result that incorrectly indicates that he or she is infected. Results obtained from the test should always be interpreted alongside additional laboratory test results.
The PhenoTest BC Kit and the Pheno System are manufactured by Accelerate Diagnostics Inc. in Tucson, Arizona.
Go to Original
"By identifying organisms and knowing earlier which antibiotics the organism is likely to respond to, health care professionals can treat patients with bloodstream infections more appropriately," said Alberto Gutierrez, PhD, director of the Office of In Vitro Diagnostics and Radiological Health at the FDAÂs Center for Devices and Radiological Health.
Unlike traditional identification and antibiotic susceptibility tests that may take 24 to 48 hours after detection in a positive blood culture to provide test results, the PhenoTest BC Kit can identify bacteria or yeast from a positive blood culture in approximately 1.5 hours. For certain organisms, the test also provides important information to guide treatment recommendations in approximately 6.5 hours after the organisms are detected from blood cultures.
The test can identify 14 different species of bacteria and two species of yeast that cause bloodstream infections, while also providing antibiotic sensitivity information on 18 selected antibiotics for a subset of the identified organisms as appropriate. The test will also identify the presence of two indicators of antibiotic resistance, which can occur when potentially harmful bacteria change in a way that reduces or eliminates the effectiveness of antibiotics.
The PhenoTest BC Kit works by measuring the similarity of the infection–causing organismÂs genetic material to DNA known to be unique to specific bacteria or yeast. Once the organism is identified, it is mixed with antibiotics and the growth of the bacteria is measured by time–lapse images. If the organism does not grow when the antibiotic is present, this means that an antibiotic can possibly be used for treatment.
The FDA reviewed the data for the PhenoTest BC Kit through the de novo premarket review pathway, a regulatory pathway for devices of a new type with low–to–moderate–risk that are not substantially equivalent to an already legally marketed device and for which special controls can be developed, in addition to general controls, to provide a reasonable assurance of safety and effectiveness of the devices. The FDAÂs decision to allow marketing was based largely on its review of the sponsorÂs primary clinical study of 1,850 positive blood cultures. In this study, the PhenoTest BC Kit provided correct identification of the bacteria or yeast in the positive blood culture more than 95 percent of the time. Results for testing whether the bacteria were sensitive to antibiotics were also accurate when compared to traditional tests.
Risks associated with use of the PhenoTest BC Kit include false positive findings, which can occur when an individual not infected with organisms that cause bloodstream infections receives a test result that incorrectly indicates that he or she is infected. Results obtained from the test should always be interpreted alongside additional laboratory test results.
The PhenoTest BC Kit and the Pheno System are manufactured by Accelerate Diagnostics Inc. in Tucson, Arizona.
Only Doctors with an M3 India account can read this article. Sign up for free or login with your existing account.
4 reasons why Doctors love M3 India
-
Exclusive Write-ups & Webinars by KOLs
-
Daily Quiz by specialty
-
Paid Market Research Surveys
-
Case discussions, News & Journals' summaries